LOT 1A
SPLICE BOLT TABLE
SPLICE
BOLTS
PLATE SIZE CLEAR TO F.F.
PLATE SIZE
A
(8) 3/4 X 3 A325T
14'-8 3/8"
6" X 3/8
6" X 3/8
01/10/2022 06:40:49am
B
(8) 3/4 X 3 A325T
14'-8 3/8"
6" X 3/8
N/A
AJ0041
FBC20
(972) 524-5407
(972) 524-5417 FAX:
PHONE:
A
B
AJ0050
PORTAL FRAME CROSS SECTION AT LINE K (OFFICE) DRAWING TITLE
PROJECT NAME EMS - Phase II
17'-6 5/16"
16'-1 3/4"
T21V0558A ADDRESS
CUSTOMER NAME SIENNA CONSTRUCTION DRAWING STATUS FOR CONSTRUCTION Baton Rouge, LA 70807 4060 T.B. Herndon Avenue
# RELEASE / REVISION DWN / CHK ENG DATE 0 PERMITS CM / ATS BMO 10/05/2021 1 Finals BTW / TJF 01/06/2022 E15 SHEET HAE
JOB NUMBER
6 1/4"
11 7/8"
18'-5"
11 7/8"
8
9
FOR COLUMN AND RAFTER MARK NUMBERS, SEE MARK NUMBER PLAN. Notes:
20'-11"
PORTAL FRAME CROSS SECTION AT LINE K (OFFICE)
(2) INDICATES THAT FLANGE BRACING IS REQUIRED ON BOTH SIDES OF THE FRAME LINE.
PROVIDED, AS REQUIRED, FOR THIS FUTURE CONDITION. THE OPPOSITE SIDE FLANGE BRACEWILL HAVE TO BE INSTALLED AT THE TIME OF EXPANSION. THESE FLANGE BRACES HAVE BEEN FOR EXPANDABLE ENDWALL RIGID FRAMES, IF FLANGE BRACING IS REQUIRED ON BOTH SIDES (2) OF AN EXPANDABLE ENDFRAME,
01/ 18/ 202 2
IF (2) IS NOT INDICATED, ONLY ONE FLANGE BRACE IS REQUIRED AND CAN BE LOCATED ON EITHER SIDE OF THE FRAME.
UNLESS INDICATED BY THE "*" SYMBOL. "*" INDICATES THE LONG SIDE OF THE INTERIOR COLUMNS. COLUMNS AT THE RIDGE ARE TYPICALLY "FLAT-TOP" COLUMNS,
FLANGE BEFORE THE HOISTING EQUIPMENT IS RELEASED. RIGID FRAMES SHALL HAVE 50% OF THEIR BOLTS INSTALLED AND TIGHTENED ON BOTH SIDES OF THE WEB ADJACENT TO EACH