LOT 1A

Notes: FOR COLUMN AND RAFTER MARK NUMBERS, SEE MARK NUMBER PLAN.

(2) INDICATES THAT FLANGE BRACING IS REQUIRED ON BOTH SIDES OF THE FRAME LINE.

FOR THE EXPANDABLE ENDWALL RIGID FRAMES, IF FLANGE BRACING IS REQUIRED ON BOTH SIDES (2) OF AN EXPANDABLE ENDFRAME, THE OPPOSITE SIDE FLANGE BRACE WILL HAVE TO BE INSTALLED AT THE TIME OF EXPANSION. THESE FLANGE BRACES HAVE BEEN PROVIDED, AS REQUIRED, FOR THIS FUTURE CONDITION.

SPLICE BOLT TABLE

SPLICE

BOLTS

CLEAR TO F.F.

PLATE SIZE

PLATE SIZE

IF (2) IS NOT INDICATED, ONLY ONE FLANGE BRACE IS REQUIRED AND CAN BE LOCATED ON EITHER SIDE OF THE FRAME.

A

(4) 3/4 X 3 A325T

13'-8 3/4"

5" X 1/4

N/A

"*" INDICATES THE LONG SIDE OF THE INTERIOR COLUMNS. COLUMNS AT THE RIDGE ARE TYPICALLY "FLAT-TOP" COLUMNS, UNLESS INDICATED BY THE "*" SYMBOL.

01/10/2022 06:40:44am

B

(4) 3/4 X 3 A325T

15'-6 7/16"

5" X 5/16

N/A

RIGID FRAMES SHALL HAVE 50% OF THEIR BOLTS INSTALLED AND TIGHTENED ON BOTH SIDES OF THE WEB ADJACENT TO EACH FLANGE BEFORE THE HOISTING EQUIPMENT IS RELEASED.

(972) 524-5407

(972) 524-5417 FAX:

12

1"

2 2 ' - 5 7 / 1 6 "

PHONE:

1 ' - 4 "

4 ' - 6 "

4 ' - 6 "

4 ' - 6 "

4 ' - 6 "

F B C 4 2

3 ' - 1 7 / 1 6 "

F B C 4 2

F B C 4 2

B

CROSS SECTION AT LINE 5 (LOADING DOCK) DRAWING TITLE

A

PROJECT NAME EMS - Phase II

FLANGE BRACING ATTACHMENT REFER TO AG0110 & AG0160 FOR

T21V0558A ADDRESS

CUSTOMER NAME SIENNA CONSTRUCTION DRAWING STATUS FOR CONSTRUCTION Baton Rouge, LA 70807 4060 T.B. Herndon Avenue

# RELEASE / REVISION DWN / CHK ENG DATE 0 PERMITS CM / ATS BMO 10/05/2021 1 Finals BTW / TJF 01/06/2022 E10 SHEET HAE

JOB NUMBER

16'-8 3/8"

14'-10"

11 7/8"

21'-4 5/8"

A

B

22'-4 1/2"

01/ 18/ 202 2

CROSS SECTION AT LINE 5 (LOADING DOCK)

Made with FlippingBook - Share PDF online