LOT 1A
1
6
94'-11"
CLPANEL RIB
STEEL LINE
(SEE ROOF SHEETING PLAN) START/FINISH DIM.
ED6010
01/13/2022 06:55:30am # RELEASE / REVISION DWN / CHK ENG DATE 0 FINALS DBO / RR 01/18/2022 STO
FINISH
1'-5 1/2"
START
1'-5 1/2"
BACK OF RAKE ANGLE
MAY VARY-REFER
TO DETAILS
B
B
BACK OF
EE6010
RAKE ANGLE
FULL WIDTH PANEL FIELD CUT FROM
*** ** 11 1/4"
2 1/2"
CUT DIM CUT DIM CUT DIM
C B A
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
327.00
27'-3 1/8"
27'-3 1/8"
A
A
EG6050 EG6005
START PANEL WIDTH DETAIL (FIELD CUT)
NOTE:
THE FINISH PANEL ALSO NEEDS TO BE CUT TO THE REQUIRED WIDTH FROM A FULL SHEET
WHEN FIELD CUTTING OR MITERING CFR ROOF PANELS, NON BE USED. ABRASIVE CUTTING TOOLS SUCH AS MECHANICAL CORRODE THE PANELS. THE USE OF NON-APPROVED CUTTING GALVALUME FINISH AND CREATE EXCESS METAL SHAVINGS THAT CAN GRINDERS, SAWS, SHEARS, OR SCISSORS CAN DAMAGE THE ABRASIVE CUTTING TOOLS SUCH AS NIBBLERS OR TIN-SNIPS SHALL DEVICES MAY VOID YOUR FACTORY WARRANTY.
ROOF SHTG PLAN WAREHOUSE & VECHICLE RESTOCKING BLDGS. DRAWING TITLE
EA6035
PROJECT NAME EMS - Phase II
272.88
584.00 272.88
272.88
272.88
272.88
584.00 272.88
272.88
272.88 584.00
584.00 272.88
584.00 272.88
272.88
584.00 272.88
584.00 272.88
584.00 272.88
272.88
272.88
584.00 272.88
272.88
272.88
584.00 272.88
584.00 272.88
584.00 272.88
584.00 272.88
584.00 272.88
584.00 272.88
584.00 272.88
272.88
584.00 272.88
272.88
584.00 272.88
584.00 272.88
584.00 272.88
584.00 272.88
584.00 272.88
584.00 272.88
584.00 272.88
272.88
272.88
584.00 272.88
584.00 272.88
584.00 272.88
584.00 272.88
584.00 272.88 EB6140
584.00 272.88
584.00 272.88
584.00 272.88
584.00 272.88
584.00 272.88
27'-3 1/8"
WAREHOUSE
T21V0558A ADDRESS
S2 SHEET CUSTOMER NAME SIENNA CONSTRUCTION Baton Rouge, LA 70807 DRAWING STATUS FOR CONSTRUCTION 4060 T.B. Herndon Avenue
JOB NUMBER
K
K
ON THIS ROOF PLANE THERMAL BLOCKS (H3300) USED TALL CLIPS (H2530) AND ERECTOR NOTE:
71'-0 15/16"
584.00
584.00
584.00
584.00
584.00
584.00
584.00
584.00
584.00
584.00
584.00
584.00
584.00
584.00
A
A
43'-9 13/16"
VEHICLE RESTOCKING
EE6010
M
M
FINISH
1'-5 1/2"
START
1'-5 1/2"
ED6010
94'-11"
ROOF SHEETING PLAN WAREHOUSE/VEHICLE RESTOCKING BLDGS. 1 6
NOTES PANELS: 24 GA. CFR - REFLECTIVE WHITE (PVDF) REFER TO SHEET S1 FOR ROOF CLIP, FASTENER, AND SEAMING PLAN
01/18/2022
REFER TO THE ROOF SHEETING ERECTION MANUAL FOR FURTHER ASSEMBLY INSTRUCTIONS. REFER TO EA6020 FOR CFR ROOF SYSTEM ERECTION AND APPLICATION REQUIREMENTS. ERECTOR NOTE: PRE-DRILLING FOR STRUCTURAL FASTENERS MAY BE REQUIRED AT PURLIN LAP LOCATIONS. REFER TO DETAIL EA6010 FOR CFR HAND CRIMPING INSTRUCTIONS. REFER TO DETAIL EA6022 FOR THERMAL BLOCK INSTALLATION. NOTE: FIELD CUTTING/WORK OF PANELS MAY BE REQUIRED FOR PROPER FIT. REFER TO DETAIL EA6025 FOR GUIDANCE TO INSTALL INSULATION WITH CFR ROOF. REFER TO DETAIL EA6026 FOR GUIDANCE FOR MAINTAINING PANEL MODULARITY WITH INSULATION. ERECTOR NOTE: (3) EXTRA ROOF PANEL (584.00) HAS BEEN PROVIDED.