LOT 1A
CLIP MK. HCJ__
JAMB EXTENSION, IF REQUIRED
S T E E L
L I N E
BOLTS (H0500) & NUTS (H0400) (2) 1/2" x 1 1/4" A307
"A"
RIGHT HAND DETAIL SHOWN, LEFT HAND OPPOSITE
S E C T I O N " A "
CLIP MK. JCT02
HEADER/SILL
(3) H1020 FASTENERS
CLIP MK. HCJ01 AT 8" MK. HCJ01 AT 9 1/2" MK. HCJ02 AT 12" (ATTACHMENT TO SLAB BY OTHERS)
GIRT
JAMB
SECTION "A"
01/10/2022 06:42:12am
JAMB
1 1/4"
H1020 FASTENER (12" O.C.)
ZEE GIRT
HEADER SHOWN, SILL OPPOSITE
GIRT
1 1/4"
LEFT HAND DETAIL SHOWN, RIGHT HAND OPPOSITE
EQ 4"/8" EQ
STEEL LINE
HEADER WRAP MK. HW ___
(3) H1020 FASTENERS
(972) 524-5407
(972) 524-5417 FAX:
(2) 1/2" x 1 1/4" A307 BUTTON HEAD BOLTS (H0510) & NUTS (H0400)
CLEAR OPENING
CLIP MK. JCT02
4" TYP. (SEE PLAN)
PHONE:
CLIP MK. HCJ01 AT 8" OR 9 1/2" MK. HCJ02 AT 12"
JAMB EXTENSION
JAMB
JAMB
JAMB
H1020 FASTENER (12" O.C.)
HEADER/SILL
STEEL LINE
STEEL LINE
SECTION "A"
"A"
SECTION "A"
JAMB EXTENSION TO ZEE GIRT
JAMB TO FINISHED FLOOR CONNECTION NOTE: USE (2) 1/2" x 1 1/4" A307 BUTTON HEAD BOLTS H0510/NUTS H0400 REFERENCE STANDARD WASHER DETAIL FOR TYPICAL WASHER REQUIREMENTS
HEADER/SILL TO JAMB CONNECTION REFERENCE STANDARD WASHER DETAIL FOR TYPICAL WASHER REQUIREMENTS
HEADER WRAP DETAIL
ZEE GIRT CONNECTION NOTE: USE (4) 1/2" x1 1/4" A307 BOLTS H0500/NUTS H0400 REFERENCE STANDARD WASHER DETAIL FOR TYPICAL WASHER REQUIREMENTS
CG0058
CG0025
CG0030
CG0050
ERECTOR NOTE: -PRE-DRILL HOLES AT NESTED ZEE GIRTS & DOUBLE CEE GIRTS IF REQUIRED. -IF THE T-CLIP IS LOCATED IN THE SAME LOCATION AS NESTED GIRT BOLTS, THE NESTED GIRT BOLTS CAN BE REMOVED.
CL COLUMN
NOTE: INSTALL CLIPS ON JAMB BEFORE STANDING JAMB. USE LEVEL TO ALIGN GIRTS ADJUST CLIP AS REQUIRED.
CLIP MK. FOC94 8"/9 1/2" CEE CLIP MK. FOC95 12" CEE CLIP MK. FOC96 8"/9 1/2" "S"
ERECTOR NOTE AT BYPASS LAP: WHEN LOCATING THE NESTED GIRT AT A GIRT LAP, THE NESTED GIRT END WILL BE HELD BACK SO THAT IT DOES NOT ENTER THE LAPPED AREA.
SHOP WELDED CLIP MK. GFI02
Wall Framing Details
DRAWING TITLE
OPNG. CLR.
CLR. OPNG.
GIRT LAP
CLIP MK. FOC94 8" / 9 1/2" CEE - (FLANGE WIDTH = 2.5" / 3.0") CLIP MK. FOC95 12" "S" - (FLANGE WIDTH = 3.63") CLIP MK. FOC96 8" / 9 1/2" "S" - (FLANGE WIDTH = 3.78" / 3.63")
COLUMN
RIGHT HAND DETAIL SHOWN, LEFT HAND OPPOSITE
PROJECT NAME EMS - Phase II
END OF NESTED GIRT
0'-1"
JAMB BELOW GIRT SHOWN MIRROR IF JAMB IS ABOVE GIRT
VARIES
3/4"
(6) H1020 FASTENERS
DOOR JAMB
FLANGE WIDTH
TYPICAL GIRT BELOW
GIRT
FACTORY PUNCHED
GIRT
SL
9/16" Ø HOLES FOR 1/2" x 1 1/4" A307 BOLTS H0500 / NUTS H0400 (FILL ALL HOLES) (THE QUANTITY OF BOLTS WILL VARY DEPENDING ON BAY SIZE)
JAMB
EQ
DOOR JAMB
T21V0558A ADDRESS
CUSTOMER NAME SIENNA CONSTRUCTION DRAWING STATUS FOR CONSTRUCTION Baton Rouge, LA 70807 4060 T.B. Herndon Avenue
# RELEASE / REVISION DWN / CHK ENG DATE 0 Finals BTW / TJF 01/04/2022 1 Finals BTW / TJF 01/06/2022 D6 SHEET HAE
4 1/4"
JOB NUMBER
CLEAR OPENING
CLIP MK. JCT01
EQ 4"/8"
3/4"
MAX. O.C. 5'-0"
1"
3" X 5" X 20' ANGLE MK. MAR01 (S.L.V.). FIELD CUT TO LENGTH AND FASTEN WITH (2) H1020 FASTENERS AT EACH END (PLACE ANGLE FROM JAMB TO FLANGE OF COLUMN). (TYPICAL 4 LOCATIONS AS SHOWN).
DOOR JAMB
3"
STEEL LINE
(2) 1/2" X 1 1/4" A307 BOLTS H0500/NUTS H0400
COLD FORMED JAMB SHOWN HOT-ROLL SIMILAR
ERECTOR NOTE AT FLUSH \INSET: WHEN LOCATING THE NESTED GIRT AT A FLUSH OR INSET CONDITION, THE NESTED GIRT END WILL BE HELD BACK TO MATCH THE GIRT BELOW IT. THE BOLTS IN THE CLIP WILL ALSO BE USED IN THE NESTED GIRT.
RIGHT HAND DETAIL SHOWN, LEFT HAND OPPOSITE
COLD FORM SHOWN, HOT-ROLL SIMILAR
SW OR EW GIRT DETAIL FRAMED OPENINGS AT FLUSH GIRT CONDITION
JAMB TO ZEE GIRT w/INTERMEDIATE GIRT NOTE: USE (4) 1/2"X 1 1/4" A307 BOLTS H0500/NUTS H0400 REFERENCE STANDARD WASHER DETAIL FOR TYPICAL WASHER REQUIREMENTS
GIRT TO JAMB CONNECTION NOTE: USE (2) 1/2" x 1 1/4" A307 BUTTON HEAD BOLTS H0510/NUTS H0400 REFERENCE STANDARD WASHER DETAIL FOR TYPICAL WASHER REQUIREMENTS
COLUMN
CG0240
NOTE: USE (4) 1/2" x 1 1/4" A307 BUTTON HEAD BOLTS H0510/NUTS H0400 REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS
CG0060
CG0059
FACTORY PUNCHED 9/16" Ø HOLES FOR 1/2" x 1 1/4" A307 BOLTS H0500 / NUTS H0400 (FILL ALL HOLES) (THE QUANTITY OF BOLTS WILL VARY DEPENDING ON BAY SIZE)
TYPICAL GIRT BELOW
MAX. O.C. 5'-0"
ERECTOR NOTE AT CORNERS: WHEN LOCATING THE NESTED GIRT AT A CORNER CONDITION, THE NESTED GIRT END WILL BE HELD BACK TO MATCH THE GIRT BELOW IT. THE BOLTS IN THE CLIP WILL ALSO BE USED IN THE NESTED GIRT.
REF. CORNER DETAILS FOR COLUMN ORIENTATION
FACTORY PUNCHED 9/16" Ø HOLES FOR 1/2" x 1 1/4" A307 BOLTS H0500 / NUTS H0400 (FILL ALL HOLES) (THE QUANTITY OF BOLTS WILL VARY DEPENDING ON BAY SIZE)
STEEL LINE
01/ 18/ 202 2
MAX. O.C. 5'-0"
FACTORY LOCATED NESTED GIRT DETAIL REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS
CM0003
CJ0005
Made with FlippingBook - Share PDF online