LOT 1A

CLIP MK. HCJ__

JAMB EXTENSION, IF REQUIRED

S T E E L

L I N E

BOLTS (H0500) & NUTS (H0400) (2) 1/2" x 1 1/4" A307

"A"

RIGHT HAND DETAIL SHOWN, LEFT HAND OPPOSITE

S E C T I O N " A "

CLIP MK. JCT02

HEADER/SILL

(3) H1020 FASTENERS

CLIP MK. HCJ01 AT 8" MK. HCJ01 AT 9 1/2" MK. HCJ02 AT 12" (ATTACHMENT TO SLAB BY OTHERS)

GIRT

JAMB

SECTION "A"

01/10/2022 06:42:12am

JAMB

1 1/4"

H1020 FASTENER (12" O.C.)

ZEE GIRT

HEADER SHOWN, SILL OPPOSITE

GIRT

1 1/4"

LEFT HAND DETAIL SHOWN, RIGHT HAND OPPOSITE

EQ 4"/8" EQ

STEEL LINE

HEADER WRAP MK. HW ___

(3) H1020 FASTENERS

(972) 524-5407

(972) 524-5417 FAX:

(2) 1/2" x 1 1/4" A307 BUTTON HEAD BOLTS (H0510) & NUTS (H0400)

CLEAR OPENING

CLIP MK. JCT02

4" TYP. (SEE PLAN)

PHONE:

CLIP MK. HCJ01 AT 8" OR 9 1/2" MK. HCJ02 AT 12"

JAMB EXTENSION

JAMB

JAMB

JAMB

H1020 FASTENER (12" O.C.)

HEADER/SILL

STEEL LINE

STEEL LINE

SECTION "A"

"A"

SECTION "A"

JAMB EXTENSION TO ZEE GIRT

JAMB TO FINISHED FLOOR CONNECTION NOTE: USE (2) 1/2" x 1 1/4" A307 BUTTON HEAD BOLTS H0510/NUTS H0400 REFERENCE STANDARD WASHER DETAIL FOR TYPICAL WASHER REQUIREMENTS

HEADER/SILL TO JAMB CONNECTION REFERENCE STANDARD WASHER DETAIL FOR TYPICAL WASHER REQUIREMENTS

HEADER WRAP DETAIL

ZEE GIRT CONNECTION NOTE: USE (4) 1/2" x1 1/4" A307 BOLTS H0500/NUTS H0400 REFERENCE STANDARD WASHER DETAIL FOR TYPICAL WASHER REQUIREMENTS

CG0058

CG0025

CG0030

CG0050

ERECTOR NOTE: -PRE-DRILL HOLES AT NESTED ZEE GIRTS & DOUBLE CEE GIRTS IF REQUIRED. -IF THE T-CLIP IS LOCATED IN THE SAME LOCATION AS NESTED GIRT BOLTS, THE NESTED GIRT BOLTS CAN BE REMOVED.

CL COLUMN

NOTE: INSTALL CLIPS ON JAMB BEFORE STANDING JAMB. USE LEVEL TO ALIGN GIRTS ADJUST CLIP AS REQUIRED.

CLIP MK. FOC94 8"/9 1/2" CEE CLIP MK. FOC95 12" CEE CLIP MK. FOC96 8"/9 1/2" "S"

ERECTOR NOTE AT BYPASS LAP: WHEN LOCATING THE NESTED GIRT AT A GIRT LAP, THE NESTED GIRT END WILL BE HELD BACK SO THAT IT DOES NOT ENTER THE LAPPED AREA.

SHOP WELDED CLIP MK. GFI02

Wall Framing Details

DRAWING TITLE

OPNG. CLR.

CLR. OPNG.

GIRT LAP

CLIP MK. FOC94 8" / 9 1/2" CEE - (FLANGE WIDTH = 2.5" / 3.0") CLIP MK. FOC95 12" "S" - (FLANGE WIDTH = 3.63") CLIP MK. FOC96 8" / 9 1/2" "S" - (FLANGE WIDTH = 3.78" / 3.63")

COLUMN

RIGHT HAND DETAIL SHOWN, LEFT HAND OPPOSITE

PROJECT NAME EMS - Phase II

END OF NESTED GIRT

0'-1"

JAMB BELOW GIRT SHOWN MIRROR IF JAMB IS ABOVE GIRT

VARIES

3/4"

(6) H1020 FASTENERS

DOOR JAMB

FLANGE WIDTH

TYPICAL GIRT BELOW

GIRT

FACTORY PUNCHED

GIRT

SL

9/16" Ø HOLES FOR 1/2" x 1 1/4" A307 BOLTS H0500 / NUTS H0400 (FILL ALL HOLES) (THE QUANTITY OF BOLTS WILL VARY DEPENDING ON BAY SIZE)

JAMB

EQ

DOOR JAMB

T21V0558A ADDRESS

CUSTOMER NAME SIENNA CONSTRUCTION DRAWING STATUS FOR CONSTRUCTION Baton Rouge, LA 70807 4060 T.B. Herndon Avenue

# RELEASE / REVISION DWN / CHK ENG DATE 0 Finals BTW / TJF 01/04/2022 1 Finals BTW / TJF 01/06/2022 D6 SHEET HAE

4 1/4"

JOB NUMBER

CLEAR OPENING

CLIP MK. JCT01

EQ 4"/8"

3/4"

MAX. O.C. 5'-0"

1"

3" X 5" X 20' ANGLE MK. MAR01 (S.L.V.). FIELD CUT TO LENGTH AND FASTEN WITH (2) H1020 FASTENERS AT EACH END (PLACE ANGLE FROM JAMB TO FLANGE OF COLUMN). (TYPICAL 4 LOCATIONS AS SHOWN).

DOOR JAMB

3"

STEEL LINE

(2) 1/2" X 1 1/4" A307 BOLTS H0500/NUTS H0400

COLD FORMED JAMB SHOWN HOT-ROLL SIMILAR

ERECTOR NOTE AT FLUSH \INSET: WHEN LOCATING THE NESTED GIRT AT A FLUSH OR INSET CONDITION, THE NESTED GIRT END WILL BE HELD BACK TO MATCH THE GIRT BELOW IT. THE BOLTS IN THE CLIP WILL ALSO BE USED IN THE NESTED GIRT.

RIGHT HAND DETAIL SHOWN, LEFT HAND OPPOSITE

COLD FORM SHOWN, HOT-ROLL SIMILAR

SW OR EW GIRT DETAIL FRAMED OPENINGS AT FLUSH GIRT CONDITION

JAMB TO ZEE GIRT w/INTERMEDIATE GIRT NOTE: USE (4) 1/2"X 1 1/4" A307 BOLTS H0500/NUTS H0400 REFERENCE STANDARD WASHER DETAIL FOR TYPICAL WASHER REQUIREMENTS

GIRT TO JAMB CONNECTION NOTE: USE (2) 1/2" x 1 1/4" A307 BUTTON HEAD BOLTS H0510/NUTS H0400 REFERENCE STANDARD WASHER DETAIL FOR TYPICAL WASHER REQUIREMENTS

COLUMN

CG0240

NOTE: USE (4) 1/2" x 1 1/4" A307 BUTTON HEAD BOLTS H0510/NUTS H0400 REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS

CG0060

CG0059

FACTORY PUNCHED 9/16" Ø HOLES FOR 1/2" x 1 1/4" A307 BOLTS H0500 / NUTS H0400 (FILL ALL HOLES) (THE QUANTITY OF BOLTS WILL VARY DEPENDING ON BAY SIZE)

TYPICAL GIRT BELOW

MAX. O.C. 5'-0"

ERECTOR NOTE AT CORNERS: WHEN LOCATING THE NESTED GIRT AT A CORNER CONDITION, THE NESTED GIRT END WILL BE HELD BACK TO MATCH THE GIRT BELOW IT. THE BOLTS IN THE CLIP WILL ALSO BE USED IN THE NESTED GIRT.

REF. CORNER DETAILS FOR COLUMN ORIENTATION

FACTORY PUNCHED 9/16" Ø HOLES FOR 1/2" x 1 1/4" A307 BOLTS H0500 / NUTS H0400 (FILL ALL HOLES) (THE QUANTITY OF BOLTS WILL VARY DEPENDING ON BAY SIZE)

STEEL LINE

01/ 18/ 202 2

MAX. O.C. 5'-0"

FACTORY LOCATED NESTED GIRT DETAIL REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS

CM0003

CJ0005

Made with FlippingBook - Share PDF online