LOT 1A
MARK NUMBER
FLAT WASHERS (1) H0210
PADDLE BRACE
ROD DIAMETER
HILLSIDE WASHERS
A307/A325 NUTS
COUPLING NUTS
MARK NUMBER
FLAT WASHERS
ROD DIAMETER
HILLSIDE WASHERS
A307/A325 NUTS
COUPLING NUTS
1 1/2" MIN.
NOTE: FOR CLARITY, THE RAFTER FLANGE IS NOT SHOWN.
RD05
(1) H0310
5/8" Ø
(1) H0930
(1) BCS07
(1) H0810
(2) H0310
H0810
2 1/2" (MAX. WIDTH)
(2) H0930
RD05
(2) H0210
5/8" Ø
SLOT
(1) H0320
3/4" Ø
RD06
(1) H0930
(1) H0220
(1) BCS08
(1) H0820
(2) H0320
RAFTER WEB
H0820
(2) H0930
(2) H0220
3/4" Ø
RD06
(1) H0325
7/8" Ø
RD07
(1) H0930
(1) H0230
(1) BCS09
(1) H0830
1 1/2" MIN.
(2) H0325
H0830
(2) H0930
7/8" Ø
RD07
(2) H0230
1" Ø
RD08-
(1) H0960
(1) H0240
(1) H0330
(1) BCL06
(1) H0840
LOOSE BRACKET CSR_ (SEE CROSS SECTION)
(1) H0450
1 1/8" Ø
RD09-
(1) H0960
(1) H0250
(1) BCL03
(1) H0850
(2) H0330
H0840
1'-0" (MAX. LENGTH)
(2) H0960
RD08
(2) H0240
1" Ø
1 1/4" Ø
RD10
(1) H0960
(1) H0260
(1) H0340
(1) BCL04
(1) H0860
GIRT
(2) H0450
H0850
(2) H0960
RD09
(2) H0250
1 1/8" Ø
Ga. = 2 1/4" Ga. = 3"
01/10/2022 06:42:07am
HILLSIDE WASHER, FLAT WASHER, AND NUT
PADDLE BRACE BOLT AND NUT PART NUMBERS
SECTION "A"
(2) H0340
(2) H0960
H0860
RD10-
(2) H0260
1 1/4" Ø
ROD DIAMETER
BOLT DIAMETER AND LENGTH
A325 BOLTS
A325 NUTS
4 1/2" 4 1/2"
SEE PLANS AND ELEVATIONS FOR BRACING MARK NUMBERS
5/8" - 7/8"
(1) H0640
(1) H0330
(1) 1" x 3 1/4"
C
L
"A"
1" - 1 1/4"
(1) H0660
(1) H0340
(1) 1 1/4" x 3 1/2"
SEE PLANS AND ELEVATIONS FOR BRACING MARK NUMBERS
(972) 524-5407
(972) 524-5417 FAX:
ROD ASSEMBLY MK. RD__-
COLUMN
WEB OF COLUMN OR RAFTER
COUPLING NUT
PLATE WASHER PWA_
WEB OF COLUMN OR RAFTER
GIRT (SHOWN) JAMB (SIMILAR)
(4) 1/2" x 2" A325 BOLTS H0603/NUTS H0300
PADDLE BRACE
PHONE:
HILLSIDE WASHER, FLAT WASHER, AND NUT
PWA25 at 2 1/4" Ga. PWA30 at 3" Ga.
COLUMN OR RAFTER
COUPLING NUT IF REQUIRED (QUANTITY VARIES)
REQ'D PARTS (6) 1/2" x 2" A325 BOLTS (H0603) (6) 1/2" NUTS (H0300)
COUPLING NUT IF REQUIRED
SECTION A
ROD OR CABLE BRACING, SEE STRUCTURAL ELEVATIONS FOR SIZE AND LOCATIONS
(1) CSR_ (1) PWA_
ROD ASSEMBLY MK. RD__-
SHOP WELDED PLATE
A
S
C
GUIDELINES FOR FIELD SLOTTING SECONDARY WEBS AT INSET OR FLUSH CONDITION
ROD BRACE DETAIL
ROD BRACE DETAIL
L
L
SEE PLAN
AF0080
AF0010
AF0020
WEB TO WEB
PADDLE BRACE TO WEB
RIGID FRAME ENDWALL RAFTER
0" @ FLUSH FRAMING 1" @ INSET FRAMING
LOOSE BRACKET CSR_ (SEE CROSS SECTION)
CLIP MK. WBP01
3'-8 1/4"
PURLIN
FBC__
FBH- COUNTER (1-999) SPECIAL LENGTH FLANGE BRACE
3'-5 1/4"
BASKET-TYPE INSULATION
PURLIN
INDICATES LENGTH OF FLANGE
BRACE IN INCHES
A
Primary Details
4" 3"
DRAWING TITLE
BLANK LENGTH
BLANK LENGTH
A ( S I M . )
5 1/2" 2"
FBN01 W/ (2) H0603 BOLTS (2) H0300 NUTS
PROJECT NAME EMS - Phase II
CEE CHANNEL - SEE PLAN FOR
(2) H0200 WASHERS BOLTED FROM THE BOTTOM
MARK NUMBERS
FASTEN TO EACH PURLIN WITH (2) H1020 @ COLD-FORMED CEE (2) H1070 @ HOT-ROLLED CEE
*
FBE__ COUNTER (01-07)
FBJ- COUNTER (1-999) SPECIAL LENGTH COPED FLANGE BRACE
CLIP MK. WBP01
PWA__ w/ (2) 1/2" x 2" A325 BOLTS H0603/NUTS H0300
8" & 12" GIRT 2"
9 1/2" GIRT 2 3/4"
COPED FLANGE BRACE
METAL OR FABRIC LINER
WIND COLUMN
BLANK LENGTH
BLANK LENGTH
FBL01 W/ (1) H0603 BOLT
COLUMN BUILT-UP/HOT-ROLLED
T21V0558A ADDRESS
CUSTOMER NAME SIENNA CONSTRUCTION DRAWING STATUS FOR CONSTRUCTION Baton Rouge, LA 70807 4060 T.B. Herndon Avenue
# RELEASE / REVISION DWN / CHK ENG DATE 0 Finals BTW / TJF 01/04/2022 1 Finals BTW / TJF 01/06/2022 D2 SHEET HAE
FLANGE BRACE OPPOSITE SIDE WHERE REQUIRED
JOB NUMBER
FINGER TIGHTEN AND DEFORM THREADS TO ALLOW FOR VERTICAL MOVEMENT.
*
RAFTER
STEEL LINE
(1)-H0603 BOLT (1)-H0300 NUT (1)-H0200 WASHER
CEE CHANNEL
PADDLE BRACE *
FBF- COUNTER (1-999) 3" X 3" 1/4" BRACE ANGLE
FBK__
FLANGE BRACE MK. FB___
CLIP WBP01
INDICATES LENGTH OF FLANGE BRACE IN INCHES
* SEE TYP. ROD BRACING DETAIL FOR PADDLE/BOLT PART MK. #'S
NOTE: 1/2" Ø X 2" A325 BOLTS ARE REQ'D FOR BOLTING FLANGE BRACES. INSTALL FBNO1 PRIOR TO INSTALLING UNDERSIDE FABRIC, VAPOR BARRIER OR LINER.
ENDWALL STEEL LINE
BLANK LENGTH
BLANK LENGTH
(1)-H0603 BOLT (1)-H0300 NUT (1)-H0200 WASHER
SECTION "A"
NOTE: USE (12) 1/2"X 2" A325 BOLTS H0603/ NUTS H0300 AT CEE CHANNEL
ENDWALL COL TO EXP. EW RAFTER CONNECTION
FLANGE BRACE WITH BASKET INSUL OR LINER AT RAFTER
FLANGE BRACE MARK NUMBERS
WIND COLUMN BRACING DETAIL - LOWSIDE WITH PURLINS REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS SEE PLANS & ELEVATIONS FOR MARK NUMBERS AND LOCATIONS
BUILT-UP/HOT-ROLLED COLUMN AT FLUSH/INSET GIRTS REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS
AD0070
SEE PLANS AND ELEVATIONS FOR FLANGE BRACE LOCATIONS, PART MARKS, & QUANTITIES
AF0830
AG0110
AG0003
ERECTOR NOTES: 1. FAR SIDE FLANGE BRACING MAY BE REQUIRED AT THE TIME OF EXPANSION. THIS FLANGE BRACING HAS BEEN INCLUDED WITH THIS PROJECT AND IS INDICATED ON ERECTION DRAWINGS AS "NS" & "FS". BOLT THE "FS" FLANGE BRACE TO THE "NS" FLANGE BRACE AS SHOWN TO STORE IT UNTIL THE FUTURE CONSTRUCTION OCCURS. 2. 1/2" Ø X 2" A325 BOLTS ARE REQ'D FOR BOLTING FLANGE BRACES. 3. INSTALL FBN01 PRIOR TO INSTALLING UNDERSIDE FABRIC, VAPOR BARRIER OR LINER.
(1) H0603 BOLT (1) H0300 NUT (1) H0200 WASHERS
(1)-H0603 BOLT TYP (1)-H0300 NUT TYP (1) H0200 WASHERS TYP
FLANGE BRACE MK. FB___
(1) H0603 BOLT (1) H0300 NUT (1) H0200 WASHERS
EXPANDABLE ENDWALL COLUMN
STORE "OPPOSITE SIDE" FLANGE BRACE HERE
FLANGE BRACE MK. FB___
COLUMN
PORTAL COLUMN
FBL01 W/ (1) H0603 BOLT
METAL OR FABRIC LINER
2" 8" & 12" GIRT 2 3/4" 9 1/2" GIRT
FBN01 W/ (2) H0603 BOLTS (2) H0300 NUTS
HORIZONTAL STIFFENER OR FLANGE BRACE PLATE
(2) H0200 WASHERS BOLTED FROM THE BOTTOM
01/ 18/ 202 2
S
L
CENTERLINE OF FRAME BASKET-TYPE INSULATION
3'-5 1/4"
GIRT
3'-8 1/4"
FLANGE BRACE AT COLUMN & PORTAL COLUMN
SEE PLANS AND ELEVATIONS FOR FLANGE BRACE PART MARKS AG0160 FLANGE BRACE WITH BASKET INSUL OR LINER @ EW COLUMN
AJ0050
AJ0041
SEE PLANS AND ELEVATIONS FOR FLANGE BRACE PART MARKS
Made with FlippingBook - Share PDF online