LOT 1A
Notes: FOR COLUMN AND RAFTER MARK NUMBERS, SEE MARK NUMBER PLAN.
(2) INDICATES THAT FLANGE BRACING IS REQUIRED ON BOTH SIDES OF THE FRAME LINE.
FOR THE EXPANDABLE ENDWALL RIGID FRAMES, IF FLANGE BRACING IS REQUIRED ON BOTH SIDES (2) OF AN EXPANDABLE ENDFRAME, THE OPPOSITE SIDE FLANGE BRACE WILL HAVE TO BE INSTALLED AT THE TIME OF EXPANSION. THESE FLANGE BRACES HAVE BEEN PROVIDED, AS REQUIRED, FOR THIS FUTURE CONDITION.
IF (2) IS NOT INDICATED, ONLY ONE FLANGE BRACE IS REQUIRED AND CAN BE LOCATED ON EITHER SIDE OF THE FRAME.
"*" INDICATES THE LONG SIDE OF THE INTERIOR COLUMNS. COLUMNS AT THE RIDGE ARE TYPICALLY "FLAT-TOP" COLUMNS, UNLESS INDICATED BY THE "*" SYMBOL.
01/10/2022 06:40:47am
SPLICE BOLT TABLE
SPLICE
BOLTS
CLEAR TO F.F.
PLATE SIZE
PLATE SIZE
RIGID FRAMES SHALL HAVE 50% OF THEIR BOLTS INSTALLED AND TIGHTENED ON BOTH SIDES OF THE WEB ADJACENT TO EACH FLANGE BEFORE THE HOISTING EQUIPMENT IS RELEASED.
A
(12) 3/4 X 3 A325T
10'-3 9/16"
6" X 1/2
8" X 1/2
B
(8) 3/4 X 3 A325T
11'-10 7/16"
6" X 1/2
6" X 1/2
C
(8) 3/4 X 3 A325T
14'-5 13/16"
8" X 1/2
6" X 1/2
(972) 524-5407
(972) 524-5417 FAX:
PHONE:
12
1"
1 1 "
4 ' - 5 "
5 4 ' - 6 1 / 4 "
4 ' - 6 "
4 ' - 6 "
4 ' - 6 "
4 ' - 6 "
4 ' - 6 "
F B C 4 4
4 ' - 6 "
F B C 4 4
4 ' - 6 "
F B C 4 4
4 ' - 6 "
4 ' - 6 "
F B C 4 4
4 ' - 6 "
CROSS SECTION AT LINE 8 (OFFICE) DRAWING TITLE
F B C 4 4
4 ' - 2 1 / 4 "
F B C 4 4
PROJECT NAME EMS - Phase II
F B C 4 4
F B C 4 6
C
3'-9" 3'-9" 2'-5" 3'-1"
T21V0558A ADDRESS
CUSTOMER NAME SIENNA CONSTRUCTION DRAWING STATUS FOR CONSTRUCTION Baton Rouge, LA 70807 4060 T.B. Herndon Avenue
B
# RELEASE / REVISION DWN / CHK ENG DATE 0 PERMITS CM / ATS BMO 10/05/2021 1 Finals BTW / TJF 01/06/2022 E13 SHEET HAE
JOB NUMBER
FBC32
FLANGE BRACING ATTACHMENT REFER TO AG0110 & AG0160 FOR
A
FBC30
17'-6 5/16"
13'-0"
1'-0"
52'-4"
1'-0"
B
K
54'-4"
01/ 18/ 202 2
CROSS SECTION AT LINE 8 (OFFICE)